📌 Image 1–2: Tube Bending for Superheater Coils
Material: ASTM A213 TP347H
These austenitic stainless steel tubes are precisely bent and subjected to post-bending heat treatment to relieve residual stresses and restore material properties. The discoloration seen is typical of heat-treated surfaces, indicating controlled thermal exposure to meet high-temperature service requirements.
📌 Image 3–4: Water Wall Panel Assembly – Spare Parts for Boiler
Fin-welded membrane panels fabricated to tight tolerances to ensure pressure part integrity and optimized heat absorption in the furnace zone. All welding joints are prepared for further NDT prior to final painting and dispatch.
At AGON PACIFIC, we ensure all fabrication processes strictly follow ASME Section I and customer specifications, including WPS/PQR, material traceability, and dimensional QC.
We are proud to announce the successful completion of the boiler wall panel replacement at the Airport Intake Panel.
✅ 100% Phased Array UT inspection completed on all weld joints, ensuring the highest standard of weld integrity.
✅ All sealing components at access and inspection openings have been reinstalled with precision to restore full airtightness and safety.
👏 Kudos to our dedicated field team for delivering high-quality workmanship and completing the job safely and efficiently.
Check out our well-organized and secure packing arrangement – designed with care to ensure that each part reaches our customer safely and in perfect condition.
At Agon Pacific, we focus not only on fabrication quality but also on how well your goods are protected during transport.
Every piece is precisely arranged, reinforced, and clearly labeled — ready for smooth delivery and installation.
🛠️ Quality fabrication
🚛 Safe and neat packing
✅ Customer satisfaction, from workshop to site